IFM SD6100 Flow rate meter

IFM SD6100

Jual IFM SD6100 Flow rate meter for gases SDR12DGXFPKG /US-100

Kami menjual IFM SD6100 di Indonesia barang-barang kami semua berkualitas Original dengan harga yang bersaing dengan Perusahaan lain

Flow rate meter for gases Specification : 

  • Precise measurement of flow, consumption and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2)
  • With switching output, analogue output and pulse output
  • Clearly visible 4-digit LED display

Product characteristics

Number of inputs and outputsdigital outputs: 2; analogue outputs: 1
Process connectionthreaded connection R 1/2 DN15

IFM SD6100Temperature monitoring

Measuring range [°C]0…60

Application

Applicationfor industrial applications
MediaArgon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°C]0…60
Pressure rating [bar]16
Pressure rating [Mpa]1.6

Electrical data

Operating voltage [V]18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]1

Inputs / outputs

Number of inputs and outputsdigital outputs: 2; analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4…20; (scalable)
Max. load [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Low flow cut-off LFC [m³/h]< 1.3
Measuring dynamics1:300
Ar
Measuring range [m³/h]0.4…122
Display range [m³/h]0…146.4
Resolution [m³/h]0.1
Set point SP [m³/h]1.1…122
Reset point rP [m³/h]0.6…121.5
Analogue start point ASP [m³/h]0…97.6
Analogue end point AEP [m³/h]24.4…122
In steps of [m³/h]0.1
CO2
Measuring range [m³/h]0.2…74.7
Display range [m³/h]0…89.7
Resolution [m³/h]0.1
Set point SP [m³/h]0.7…74.7
Reset point rP [m³/h]0.4…74.4
Analogue start point ASP [m³/h]0…59.8
Analogue end point AEP [m³/h]14.9…74.7
In steps of [m³/h]0.1

 Volumetric flow quantity monitoring

Pulse value0.001…1 000 000 m³
In steps of0.001…1000 m³
Pulse length [s]0,012…2
N2
Measuring range [m³/h]0.2…75
Display range [m³/h]0…90
Resolution [m³/h]0.1
Set point SP [m³/h]0.7…75
Reset point rP [m³/h]0.4…74.7
Analogue start point ASP [m³/h]0…60
Analogue end point AEP [m³/h]15…75
In steps of [m³/h]0.1

Temperature monitoring

Measuring range [°C]0…60
Display range [°C]-12…72
Resolution [°C]0.2
Set point SP [°C]0.4…60
Reset point rP [°C]0…59.8
Analogue start point [°C]0…48
Analogue end point [°C]12…60
In steps of [°C]0.2

IFM SD6100 Accuracy / deviations

Flow monitoring

Repeatability [% of the measured value]± 1,5
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15)

Temperature monitoring

Accuracy [K]± 2; (medium flow in the limit area of the flow measurement range)
Response times

Flow monitoring

Response time [s]0.1; (dAP = 0)
Damping for the switching output dAP in steps [s]0 – 0,2 – 0,4 – 0,6 – 0,8 – 1
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
IO-Link device ID265 d / 00 01 09 h
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time [ms]4.1

Operating conditions

Ambient temperature [°C]0…60
Storage temperature [°C]-20…85
Max. relative air humidity [%]90
ProtectionIP 65
Tests / approvals
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
Vibration resistance
DIN IEC 68-2-65 g (55…2000 Hz)
MTTF [years]227
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight [g]963.5
MaterialsPBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts)stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised
Tightening torque [Nm]50
Process connectionthreaded connection R 1/2 DN15

Displays / operating elements

Display
Display unit4 x LED, green (Nl/min, Nm³/h, Nm³, °C)
function display1 x LED, yellow
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Display unitNl/min; Nm³/h; Nm³; °C
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12

Datasheet Katalog IFM SD6100